Check energy-code (LPD) compliance
Read the watts-per-area figure for an area and see how it stacks up against ASHRAE 90.1 and IECC lighting power density limits.
4 steps · 3 min read
Energy codes cap how much lighting power you can install per unit of floor area. Watching the LPD readout as you design keeps you from over-lighting a space and having to strip fixtures out later — and it reads in whichever unit system you work in.
Select an area with fixtures
Lighting Power Density (LPD) is a per-area measure, so select a calculation area that has fixtures contributing to it. The energy readout appears with the area's properties in the right panel.
Read the watts-per-area figure
OpenLumen totals the input watts of the fixtures over the area and divides by its size to get a power density. It's shown in your active units — W/ft² in Imperial, W/m² in Metric — so the same design reads correctly either way.
Understand the compliance status
The figure is compared against the lower (stricter) of the ASHRAE 90.1-2019 and IECC 2021 limits for the selected space type. You'll see one of three states:
- LPD Compliant (green) — at or under the limit.
- LPD Near Limit (amber) — within 10% over the limit.
- LPD Exceeds Limit (red) — more than 10% over.
A tooltip breaks out both the ASHRAE and IECC limits and the code-table sections they come from.
Treat it as guidance, not a stamp
The check carries a *"Guidance only — not official compliance"* note for a reason: it's a fast sanity check on your design, not a substitute for an energy model or a code official's review. Use it to catch an over-lit space early, then adjust fixture count, wattage, or the per-type output multiplier to bring it in line.